# Methodology

## The shape of the calculation

Emissions, expressed in kilograms of CO₂-equivalent (CO₂eq), are the product of two factors:

```
E = Energy consumed by the computational infrastructure, in kilowatt-hours
C = Carbon intensity of that electricity, in g CO₂ emitted per kilowatt-hour
```

```
Emissions (kgCO₂eq) = E × C
```

CodeCarbon computes `E` by sampling CPU, GPU and RAM power at a fixed interval and integrating over time, and resolves `C` from the machine's location or cloud region. Both halves have fallbacks, and which fallback ran is what determines how much you should trust the result.

Expanded, that is four terms:

```
emissions = Σ_intervals (power × Δt × PUE) × carbon_intensity
```

- `power` — watts drawn by the CPU, GPU and RAM at the moment of sampling.
- `Δt` — the sampling interval, `measure_power_secs`, 15 seconds by default. Power × Δt is energy; summing over every interval gives the energy of the run.
- `PUE` — power usage effectiveness, an optional multiplier for datacentre overhead such as cooling. It defaults to 1.0, meaning no overhead assumed.
- `carbon_intensity` — grams of CO₂-equivalent emitted per kilowatt-hour on the grid the machine draws from.

`E` above is therefore the **PUE-inflated** energy: a `pue` you set is already folded into every energy figure CodeCarbon reports, per component. This matters when you do arithmetic with the CSV columns — see [Power Usage Effectiveness](<#power-usage-effectiveness-pue>).

| Half of the formula | Best case | Worst case |
| --- | --- | --- |
| `E` — energy | Hardware energy counters (RAPL, EMI, NVML) | A CPU model's catalogue TDP scaled by CPU load |
| `C` — carbon intensity | Live grid intensity from Electricity Maps | The 475 gCO₂eq/kWh world average |

Nothing in the output states which case applied to `C`. For `E`, the log line emitted at startup names the CPU backend.

## Energy: what is measured, what is modelled

Power is sampled at `measure_power_secs`, default 15 seconds, configurable when instantiating the tracker. Energy is the integral of power over time: `Energy = Power × Time`.

| Component | Best available source | Modelled fallback |
| --- | --- | --- |
| CPU | Intel RAPL (Linux), Raspberry Pi 5 PMIC, Energy Meter Interface (Windows 11), `powermetrics` (macOS), Intel Power Gadget (legacy) | TDP × CPU load, or a flat constant |
| GPU | NVML via `nvidia-ml-py` (Nvidia) or AMDSMI (AMD) — a direct device reading | none; without a supported GPU library, GPU is not counted |
| RAM | the PMIC DRAM rails on a Raspberry Pi 5; RAPL only on specific hardware | modelled from an estimated DIMM count |

CodeCarbon does not separately model disk I/O, network transfer, displays, cooling or other peripherals. Those are usually small for local, code-level experiments, and they are not exposed through the same low-overhead interfaces. They can matter for workloads dominated by data movement, storage or distributed communication.

### Tracking modes

The `tracking_mode` parameter (`"machine"` or `"process"`, default `"machine"`) controls the **scope** of attribution, independently of which measurement backend was selected.

**Machine mode** measures the whole hardware stack. It is the straightforward reading, and the right one on a dedicated machine.

**Process mode** estimates the share attributable to your Python process and its children, by sampling their CPU time against total CPU capacity. This is a software approximation — it does **not** read per-process hardware counters — and is preferable on shared machines.

> [!WARNING]
>
> **GPU is always machine-wide**
>
> Process mode affects CPU and RAM attribution only. GPU power is measured at the device level, so on a shared GPU CodeCarbon still attributes the **entire GPU's** consumption to your run.

> [!WARNING]
>
> **On the estimation path, `tracking_mode` also changes the power model**
>
> When CodeCarbon falls back to `cpu_load` mode, `tracking_mode` selects not just the attribution scope but a **different power curve** — cubic with a 10% floor for machine mode, linear with no floor for process mode. See [The two cpu\_load models](<#the-two-cpu_load-models>). On the hardware-counter paths (RAPL, EMI, NVML) this does not apply.

### Power Usage Effectiveness (PUE)

If you set `pue`, it is applied inside the measurement loop to **each component's energy** before accumulation, in `_do_measurements` ([`emissions_tracker.py`](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/emissions_tracker.py>)):

```
energy *= self._pue
```

This means `cpu_energy`, `gpu_energy` and `ram_energy` in the CSV are **already inflated by the PUE**, not just `energy_consumed` and `emissions`. Do not multiply by PUE a second time when reusing the per-component columns. Water consumption is derived from the post-PUE energy in the same loop.

## CPU

### Which backend gets chosen

This is the part of CodeCarbon most often misread. The selection logic is `ResourceTracker.set_CPU_tracking` in [`core/resource_tracker.py`](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/core/resource_tracker.py>), and it is evaluated strictly in this order — the first row that applies wins.

Rows 3–10 are the platform backends tried by `_try_platform_cpu_backend`. If none of them matches, `set_CPU_tracking` delegates to `_setup_fallback_tracking`, which is where rows 11 and 12 are decided. Row 0 is checked before all of them.

| \# | Condition | Result | Source |
| --- | --- | --- | --- |
| 0 | `force_mode_constant` is set | `constant` mode, from `force_cpu_power` if set, else the TDP. **Every other row is skipped**, including `force_mode_cpu_load` | `set_CPU_tracking` |
| 1 | `force_cpu_power` is set | **Every platform backend is skipped** — RAPL is not consulted even if it is available — and your value becomes the TDP handed to row 11 or row 12 below. It is not the reported power. | `set_CPU_tracking` |
| 2 | `force_mode_cpu_load` is set, `psutil` present, and a TDP is known (or `force_cpu_power` is set) | `cpu_load` mode | `set_CPU_tracking`, `_setup_cpu_load_mode` |
| 3 | Linux **and** RAPL files readable | `intel_rapl` — hardware energy counters | `_try_platform_cpu_backend` |
| 4 | Raspberry Pi 5 (`vcgencmd pmic_read_adc` answers) | `raspberry` — PMIC power readings | `_try_platform_cpu_backend`, `cpu.is_raspberry` |
| 5 | macOS **and** Apple Silicon **and** `psutil` present | `cpu_load` mode | `_try_platform_cpu_backend`, `_setup_cpu_load_fast` |
| 6 | macOS **and** Apple Silicon **and** no `psutil` **and** `powermetrics` usable | `powermetrics` | `_try_platform_cpu_backend` |
| 7 | macOS **and** Intel **and** Intel Power Gadget installed | `intel_power_gadget` | `_try_platform_cpu_backend` |
| 8 | macOS **and** Intel **and** `powermetrics` usable | `powermetrics` | `_try_platform_cpu_backend` |
| 9 | Windows **and** EMI available | `windows_emi` — hardware energy counters | `_try_platform_cpu_backend` |
| 10 | Windows **and** Intel Power Gadget installed | `intel_power_gadget` | `_try_platform_cpu_backend` |
| 11 | none of the above, `psutil` present | `cpu_load` mode | `_setup_fallback_tracking` |
| 12 | none of the above, no `psutil` | `constant` mode | `_setup_fallback_tracking` |

Two consequences worth stating plainly, because they surprise people:

- **`force_cpu_power` disables hardware measurement, and it is not the reported power.** Setting it on a machine with working RAPL replaces a real counter with an estimate. Because `psutil` is a hard dependency, the estimate is normally `cpu_load` mode with your value as the TDP, so in machine mode `force_cpu_power=65` reports `65 × (0.1 + 0.9 × load³)` watts, between 6.5 W and 65 W, not a flat 65 W. It becomes a flat figure only with `force_mode_constant` (row 0) or on an installation without `psutil` (row 12), and then it is half your value, not your value (`constant` mode below). Unlike a registry TDP, it is used as given: it is not multiplied by the CPU package count.
- **On Apple Silicon, `powermetrics` is effectively unreachable.** `psutil` is a hard dependency of CodeCarbon, so row 5 fires before row 6 in every normal installation. The `sudo`-granting instructions that used to appear here describe a path the code no longer takes.

### The fallback constants

When no hardware counter is available, CodeCarbon needs a power figure. It gets one from the following ladder, in `TDP._main` in [`core/cpu.py`](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/core/cpu.py>):

| Situation | TDP used | Constant | Source |
| --- | --- | --- | --- |
| CPU model detected and present in the TDP registry (2000+ Intel and AMD parts) | the registry value | — | `TDP._get_cpu_power_from_registry` |
| CPU model detected but **absent** from the registry, `psutil` present | `threads × 4 W` | `DEFAULT_POWER_PER_CORE = 4` | `core/cpu.py` |
| CPU model absent from the registry and no `psutil`, or the model could not be detected at all | `85 W` | `POWER_CONSTANT = 85` | `external/hardware.py`, applied in `CPU.from_utils` |

A TDP found by this ladder is multiplied by the physical CPU package count (in `set_CPU_tracking`) to give the machine-level ceiling; the 85 W constant is not.

That ceiling is then turned into an instantaneous power reading in one of two ways, and **the two ways are not the same**:

- **`cpu_load` mode** — see the next section. **It uses two different power models depending on `tracking_mode`.**
- **`constant` mode** — reached with `force_mode_constant`, or when `psutil` is unavailable — applies a flat half of TDP, whatever the `tracking_mode` (`CPU._get_power_from_cpus` in [`external/hardware.py`](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/external/hardware.py>)):

  ```
  power = TDP × CONSUMPTION_PERCENTAGE_CONSTANT   # CONSUMPTION_PERCENTAGE_CONSTANT = 0.5
  ```

  `CONSUMPTION_PERCENTAGE_CONSTANT = 0.5` is defined at the top of `external/hardware.py`.

### The two cpu\_load models

`cpu_load` mode does not have one power model. It has two, selected by `tracking_mode` inside [`CPU._get_power_from_cpu_load`](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/external/hardware.py>) in `external/hardware.py`. They differ in shape, not only in scope, and the difference is large at low load.

|  | `tracking_mode="machine"` | `tracking_mode="process"` |
| --- | --- | --- |
| Load source | system-wide CPU busy time since the previous reading, from `psutil.cpu_times()` (`SystemCPULoadMeter`) | per-process CPU-time deltas over wall clock, summed across the process and its children |
| Normalisation | none — already a 0–100% figure | divided by core count |
| Curve | **cubic** | **linear** |
| Idle floor | **10% of TDP** | **none** — 0% load gives 0 W |

```
# machine mode
load_factor = 0.1 + 0.9 * ((cpu_load / 100.0) ** 3)
power = tdp * load_factor
```

```
# process mode
cpu_load_normalized = cpu_load / self._cpu_count
power = self._tdp * cpu_load_normalized / 100
```

> [!WARNING]
>
> **The same workload measured both ways will not differ only by scope**
>
> Switching `tracking_mode` silently swaps the power model. At low utilisation the two diverge sharply: machine mode never reports below 10% of TDP, while process mode reports proportionally to load and reaches zero. At 50% load, machine mode gives `0.1 + 0.9 × 0.125 = 21%` of TDP, while a process saturating half the cores gives 50% of TDP — more than double, from the same underlying utilisation.
>
> If you compare a machine-mode run against a process-mode run and the numbers disagree by more than the attribution scope explains, this is why.

**None of these shape choices is sourced in the code.** The cubic exponent, the 0.1 floor in machine mode, and the absence of any floor in process mode are all asserted, with no comment, citation or fitting procedure anywhere in the module. They are plausible defaults, not measurements.

[Accuracy and validation](<https://docs.codecarbon.io/latest/explanation/accuracy/index.md#the-cpu-load-tdp-fallback-measured>) reports how far this fallback lands from measured RAPL energy — **in machine mode only**; those figures do not transfer to process mode.

### Per-platform notes

**Linux.** Energy is read from Intel RAPL files under `/sys/class/powercap/intel-rapl/subsystem` ([Weaver](<https://web.eece.maine.edu/~vweaver/projects/rapl/>)). Every CPU listed there is tracked. The files must exist *and* be readable by the running user; on many distributions they are root-only by default. Despite the "Intel RAPL" name, AMD processors are supported since Linux kernel 5.8. On multi-die CPUs, package domains can mirror the same socket-wide energy counter. CodeCarbon flags counters holding the same value at startup and drops a duplicate only once it has also accumulated the very same energy over a measurement interval, so CPU energy is neither counted once per die nor missing a genuine package that coincidentally held the same value. See [RAPL Metrics](<https://docs.codecarbon.io/latest/explanation/rapl/index.md>) for the details.

**Windows.** Tracks Intel and AMD processor energy consumption using the [Energy Meter Interface (EMI)](<https://learn.microsoft.com/en-us/windows-hardware/drivers/powermeter/energy-meter-interface>), through which Windows 11 exposes the CPU RAPL energy counters (the same hardware counters CodeCarbon reads on Linux). It is built into the OS: no third-party driver, no administrator rights and no extra dependency are needed.

*Note*: EMI reports CPU power only on Windows 11 running on bare metal (on Windows 10, only on devices with dedicated metering hardware, such as the Surface Book). On virtual machines or older Windows versions, CodeCarbon falls back to the CPU-load estimation mode described above.

*Note*: as on Linux, only package channels are measured. Windows exposes one EMI device per metered component, so a CPU shows up as one device per core (`RAPL_Package0_Core3_CORE`) next to the device holding the package channel (`RAPL_Package0_PKG`). Those per-core channels, like `PP0`/`PP1`, are subdomains of the package: measuring both would count the same energy twice, so CodeCarbon keeps the package channels only. On multi-die CPUs where every die mirrors the same socket-wide counter, the duplicates are detected and dropped as well. The `DRAM` channels are excluded too, unless the [`rapl_include_dram`](<https://docs.codecarbon.io/latest/how-to/configuration/index.md#including-dram-in-the-cpu-measurement>) option is enabled.

**macOS, Intel.** Tracks Intel processors energy consumption using the `Intel Power Gadget`. You need to install it yourself from this [source](<https://www.intel.com/content/www/us/en/developer/articles/tool/power-gadget.html>). Intel has since discontinued the tool; this is a known limitation, tracked in [issue \#457](<https://github.com/mlco2/codecarbon/issues/457>).

**macOS, Apple Silicon.** The Apple Silicon chip contains both CPU and GPU, and `powermetrics` can read both, but it requires `sudo` and — as row 5 of the table above shows — `cpu_load` mode is selected first whenever `psutil` is installed, which is the normal case. There is no known way to read Apple Silicon energy without administrative rights; if you know of one, please [open an issue](<https://github.com/mlco2/codecarbon/issues>).

**Legacy Intel Power Gadget** is retained on all platforms for machines where it is still installed, but it should not be relied on for new setups.

### CPU hardware background

The CPU die is the processing unit itself. It's a piece of semiconductor that has been sculpted/etched/deposited by various manufacturing processes into a net of logic blocks that do stuff that makes computing possible. The processor package is what you get when you buy a single processor. It contains one or more dies, plastic/ceramic housing for dies and gold-plated contacts that match those on your motherboard. RAPL and EMI report at the package level, which is why CodeCarbon deduplicates subdomain channels.

In Linux kernel, energy\_uj is a current energy counter in micro joules. It is used to measure CPU core's energy consumption.

Micro joules is then converted in kWh, with formula `kWh=energy * 10** (-6) * 2.77778e-7`.

For example, on a laptop with Intel(R) Core(TM) i7-7600U, Code Carbon will read two files : /sys/class/powercap/intel-rapl/intel-rapl:1/energy\_uj and /sys/class/powercap/intel-rapl/intel-rapl:0/energy\_uj

For how a rolling energy counter becomes a power figure, see [Power Estimation](<https://docs.codecarbon.io/latest/explanation/power-estimation/index.md>). For the primary sources on RAPL, see [Khan et al., *RAPL in Action*](<https://dl.acm.org/doi/10.1145/3177754>) and [Weaver, *Reading RAPL energy measurements from Linux*](<https://web.eece.maine.edu/~vweaver/projects/rapl/>); this [blog post](<https://blog.chih.me/read-cpu-power-with-RAPL.html>) is a useful informal walkthrough.

## GPU

Nvidia GPU energy is read through `nvidia-ml-py` (installed with the package), which queries NVML — a direct device reading, not a model. There is no fallback: if NVML is unavailable, GPU energy is not counted at all rather than estimated. On Apple Silicon under `powermetrics`, the integrated GPU is reported as a separate `AppleSiliconChip` device.

## RAM

There is no hardware counter for RAM power on the platforms CodeCarbon supports, and reading the actual DIMM configuration needs root. So CodeCarbon runs a two-stage estimate in [`external/ram.py`](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/external/ram.py>). The exception is the Raspberry Pi 5, where the PMIC measures the DRAM rails and that reading replaces the estimate. And some RAPL interface could expose RAM energy but they are rare.

**Stage 1 — guess the DIMM count** from total RAM, using a hardcoded step function (`RAM._estimate_dimm_count`):

| Total RAM | Assumed DIMMs |
| --- | --- |
| ≤ 2 GB | 1 |
| ≤ 16 GB | 2 |
| 17–64 GB | 4 |
| 65–128 GB | 8 |
| \> 128 GB | `ceil(total_GB / largest_fitting_DIMM_size)`, capped at 32 |

**Stage 2 — assign power per DIMM** with a marginal-efficiency taper (`RAM._calculate_ram_power`):

| Parameter | Value |
| --- | --- |
| Base power per DIMM, x86 | `RAM_SLOT_POWER_X86 = 5` W |
| Base power per DIMM, ARM | 1.5 W |
| DIMMs 1–4 | 100% of base each |
| DIMMs 5–8 | 90% of base each |
| DIMMs 9–16 | 80% of base each |
| DIMMs 17+ | 70% of base each |
| Minimum, x86 | 10 W (2 DIMMs × 5 W) |
| Minimum, ARM | 3 W |

The only citation anywhere in the module is a pre-v3 [Crucial FAQ](<https://www.crucial.com/support/articles-faq-memory/how-much-power-does-memory-use>) recording the *old* 3 W-per-8 GB rule (in the `RAM` class docstring), which the current model replaced. **Neither the 5 W figure nor any of the 0.9/0.8/0.7 multipliers has a source in the code.** They are asserted values that appear reasonable, not measurements.

The change from v2's 3 W-per-8 GB to per-DIMM power is nonetheless directionally right: RAM power tracks the number of physical modules, not the number of gigabytes. A server with 1 TB across 8 DIMMs does not draw 128× a laptop's RAM power. Worked examples from the model above:

- 8 GB laptop → 2 DIMMs → **10 W**
- 32 GB desktop → 4 DIMMs → **20 W**
- 64 GB desktop → 4 DIMMs → **20 W** (identical to 32 GB)
- 128 GB server → 8 DIMMs → **38 W**
- 1 TB server → 8 DIMMs → **38 W** (identical to 128 GB)

**If you can measure or look up your real configuration, do so and override the estimate.** On Linux:

```
sudo lshw -C memory -short | grep DIMM

/0/37/0    memory    4GiB DIMM DDR4 Synchrone Unbuffered (Unregistered) 2400 MHz
/0/37/1    memory    4GiB DIMM DDR4 Synchrone Unbuffered (Unregistered) 2400 MHz
/0/37/2    memory    4GiB DIMM DDR4 Synchrone Unbuffered (Unregistered) 2400 MHz
/0/37/3    memory    4GiB DIMM DDR4 Synchrone Unbuffered (Unregistered) 2400 MHz
```

Four slots, so pass `force_ram_power=20` (4 × 5 W) — or better, a wattage you have measured — to the tracker. `force_ram_power` bypasses the whole heuristic.

Old machine could use 2 Mb memory stick, where modern servers will use 512 Mb memory stick, making our heuristic innacurate.

## Carbon intensity

Carbon intensity is the weighted average emissions of the energy sources feeding the grid the machine is drawing from. Fossil fuels — coal, petroleum, natural gas — carry high intensities; solar, hydro, wind, nuclear, biomass and geothermal carry low ones. The local mix determines the figure.

[![Grid Energy Mix](<https://docs.codecarbon.io/latest/images/grid_energy_mix.png>)](<https://docs.codecarbon.io/latest/images/grid_energy_mix.png>)

### Resolution order

CodeCarbon resolves `C` through the ladder below, implemented in [`core/emissions.py`](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/core/emissions.py>). The first level that answers wins.

| \# | Level | Condition | Data | Source |
| --- | --- | --- | --- | --- |
| 1 | Forced value | `force_carbon_intensity_g_co2e_kwh` is set | your number | `get_cloud_emissions`, `get_private_infra_emissions` |
| 2 | Cloud region | running on a recognised cloud provider **and** the provider/region pair is in `impact.csv` | [`data/cloud/impact.csv`](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/data/cloud/impact.csv>) | `get_cloud_emissions` |
| 3 | Electricity Maps | an API token is configured | live grid intensity by lat/lon or country code | `get_private_infra_emissions`, `core/electricitymaps_api.py` |
| 4 | Regional | country is US, Canada, China, Sweden, Norway or Finland **and** a region/bidding zone is known | see [Regional data](<#regional-data>) below | `get_region_emissions` |
| 5 | Country | the country ISO code is in the energy-mix file | [`global_energy_mix.json`](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/data/private_infra/global_energy_mix.json>), from [Our World in Data](<https://ourworldindata.org/grapher/carbon-intensity-electricity>) | `get_country_emissions` |
| 6 | World average | nothing above resolved | **475 gCO₂eq/kWh**, from the [IEA](<https://www.iea.org/reports/global-energy-co2-status-report-2019/emissions>) | `carbon_intensity_per_source.json`, applied in `get_cloud_emissions` and `get_country_emissions` |

Some countries lack data for the most recent year, in which case the most recent available year is used.

For a cloud region, the location comes from `impact.csv`. If the row has no state, CodeCarbon uses the city as the region.

> [!WARNING]
>
> **The fallbacks are silent**
>
> Every step down this ladder degrades quietly. If your cloud provider and region are not in `impact.csv` — and **AWS and Azure publish no per-region carbon intensity at all; only GCP does** — CodeCarbon logs a warning and continues with levels 3 to 5 for the machine's location, or uses the 475 g world average if no location is known (`get_cloud_emissions`). Likewise an unknown country ISO code drops straight to the world average (`get_country_emissions`).
>
> **Nothing in the CSV, the API payload or the emissions figure records which level answered.** A run resolved from a live Electricity Maps reading and a run resolved from the world average produce output of identical shape. If the provenance matters to you, check the startup logs at `WARNING` level or set `force_carbon_intensity_g_co2e_kwh` explicitly so there is no ambiguity.

The country values come from the [Our World in Data energy dataset](<https://ourworldindata.org/grapher/carbon-intensity-electricity>). The carbon intensity is [Ember](<https://ember-energy.org/data/yearly-electricity-data/>)'s lifecycle carbon intensity of electricity generation, in gCO₂eq/kWh, so it is higher than figures that count only the emissions of operating the power plants. The electricity mix combines the data of Ember and the Energy Institute. Each country uses its most recent year with data, given by the `year` field of the file. A lifecycle carbon intensity cannot be zero, so a zero in the dataset is stored as `null` and the carbon intensity is computed from the electricity mix instead (this is the case of the Central African Republic, whose electricity is all hydroelectricity). To refresh them, run `uv run python codecarbon/data/private_infra/update_global_energy_mix.py`.

### Regional data

For some countries, CodeCarbon has sub-national carbon intensity data and uses it when the geolocation service (or the `region` parameter) reports a region in one of them:

| Country | Granularity | Source |
| --- | --- | --- |
| United States | State | [EPA eGRID2023 emission rate per state](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/data/private_infra/2023/usa_emissions.json>) |
| Canada | Province and territory | [ECCC NIR 2026 consumption intensity per province and territory, 2024](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/data/private_infra/2024/canada_emissions.json>) |
| Sweden, Norway, Finland | Electricity bidding zone (SE1-SE4, NO1-NO5, FI) | [ENTSO-E generation mix, 2025](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/data/private_infra/nordic_emissions.json>) |
| China | Province (30 provinces, municipalities and autonomous regions) | [MEE/NBS Announcement 2025 No. 47, 2023 factors](<https://github.com/mlco2/codecarbon/blob/master/codecarbon/data/private_infra/2023/china_provincial_emissions.json>) |

For the United States, the values are the eGRID2023 state annual CO₂eq total output emission rates published by the U.S. Environmental Protection Agency ([source](<https://www.epa.gov/egrid/download-data>)). They range from 24 gCO₂eq/kWh in Vermont to 893 gCO₂eq/kWh in West Virginia, with a national value of 350 gCO₂eq/kWh. To update them when EPA publishes a new edition, download the eGRID data workbook and run `uv run --with openpyxl python codecarbon/data/private_infra/update_usa_emissions.py <workbook> --year <year>`.

For China, the values are the official provincial average electricity CO₂ emission factors published by the Ministry of Ecology and Environment and the National Bureau of Statistics ([source](<https://www.mee.gov.cn/xxgk2018/xxgk/xxgk01/202512/t20251231_1139517.html>)). They range from 133 gCO₂/kWh in Yunnan to 680 gCO₂/kWh in Tianjin, whereas the national value is 525 gCO₂eq/kWh. Note that these official factors count CO₂ only (no other greenhouse gases, no lifecycle emissions), whereas the per-country values are in CO₂eq. Tibet, Hong Kong, Macao and Taiwan are not in the official table and use the country value.

For Canada, the provincial and territorial values are 2024 **consumption** intensities in g CO₂e/kWh from Environment and Climate Change Canada's *National Inventory Report 1990–2024* (2026), Annex 7, Table A7-6 — the `.xlsx` file published at the [ECCC data portal](<https://data-donnees.az.ec.gc.ca/data/substances/monitor/canada-s-official-greenhouse-gas-inventory/C-Tables-Electricity-Canada-Provinces-Territories>). These consumption intensities include grid losses and other relevant emissions. They range from 2.6 gCO₂eq/kWh in Quebec to 760 gCO₂eq/kWh in Nunavut. CodeCarbon uses them directly, the same way as the US state values; the unit of each regional file is stated in its `_unit` entry. CodeCarbon 3.3 and earlier estimated the Canadian values from a 2023 provincial energy mix with fossil-only emission factors (`2023/canada_energy_mix.json`, kept in the repository for reference but no longer packaged).

When a region is not found in the regional data, CodeCarbon falls back to the country value.

### The legacy per-fuel table

Before per-country intensities were available from Our World in Data, CodeCarbon derived intensity from a country's electricity *mix* using this table. It is retained for the regional Canadian data, which is published as a mix rather than as an intensity.

| Energy Source | Carbon Intensity (kg/MWh) |
| --- | --- |
| Coal | 995 |
| Petroleum | 816 |
| Natural Gas | 743 |
| Biofuel | 230 |
| Biomass | 230 |
| Geothermal | 38 |
| Hydroelectricity | 26 |
| Nuclear | 29 |
| Solar | 48 |
| Waste | 230 |
| Wind | 26 |

*Carbon Intensity Across Energy Sources*

Sources:

- [for fossil energies](<https://github.com/responsibleproblemsolving/energy-usage#conversion-to-co2>)
- [for renewables energies](<http://www.world-nuclear.org/uploadedFiles/org/WNA/Publications/Working_Group_Reports/comparison_of_lifecycle.pdf>)
- [for biomass and biofuel](<https://www.ipcc.ch/site/assets/uploads/2018/02/ipcc_wg3_ar5_annex-iii.pdf>) (IPCC AR5 WG3 Annex III, Table A.III.2, median for "Biomass — dedicated")
- [for waste](<https://github.com/electricitymaps/electricitymaps-contrib/blob/b7469384a7/electricitymap/contrib/parsers/ENTSOE.py#L123>) (the biomass factor, following Electricity Maps, which groups waste with biomass)

Then, for example, if the Energy Mix of the Grid Electricity is 25% Coal, 35% Petroleum, 26% Natural Gas and 14% Nuclear:

```
Net Carbon Intensity = 0.25 * 995 + 0.35 * 816 + 0.26 * 743 + 0.14 * 29 = 731.59 kgCO₂/MWh
```

## Measurement cadence

CodeCarbon runs a scheduler that takes a measurement every `measure_power_secs` (default 15 s), started by `start()` and stopped by `stop()`. The measurement itself is fast and the memory footprint is small, so overhead is not significant at the default interval.

A second scheduler, `scheduler_monitor_power`, samples power once per second. It exists for hardware that exposes instantaneous power but no cumulative energy counter — `cpu_load` mode in particular — so that the per-interval energy is an average of many samples rather than a single instant.

## Estimation of Equivalent Usage Emissions

The CodeCarbon dashboard provides equivalent emissions and energy usage comparisons to help users better understand the carbon impact of their activities. These comparisons are based on the following assumptions:

### Car Usage

- **Emission factor**: *0.12 kgCO₂ per kilometer driven*.
- This value is derived from the average emissions of a European passenger car under normal driving conditions.

Source : [European Environment Agency](<https://co2cars.apps.eea.europa.eu/?source=%7B%22track_total_hits%22%3Atrue%2C%22query%22%3A%7B%22bool%22%3A%7B%22must%22%3A%5B%7B%22constant_score%22%3A%7B%22filter%22%3A%7B%22bool%22%3A%7B%22must%22%3A%5B%7B%22bool%22%3A%7B%22should%22%3A%5B%7B%22term%22%3A%7B%22year%22%3A2023%7D%7D%5D%7D%7D%2C%7B%22bool%22%3A%7B%22should%22%3A%5B%7B%22term%22%3A%7B%22scStatus%22%3A%22Provisional%22%7D%7D%5D%7D%7D%5D%7D%7D%7D%7D%5D%7D%7D%2C%22display_type%22%3A%22tabular%22%7D>)

### TV Usage

- **Energy consumption**: *138 Wh per day based on average use*.
- This assumes:

  - An average daily usage of 6.5 hours.
  - A modern television with a power consumption of approximately *21.2 W per hour*.

Source : [The French Agency for Ecological Transition](<https://agirpourlatransition.ademe.fr/particuliers/maison/economies-denergie-deau/electricite-combien-consomment-appareils-maison>)

### US Citizen Weekly Emissions

- **Annual emissions**: *13.3 tons of CO₂ equivalent per year* for an average US citizen.
- **Weekly emissions**: This value is divided by the 52 weeks in a year to estimate weekly emissions:

\\\[\\text{Weekly Emissions} = \\frac{\\text{Annual Emissions (tons)}}{52}\\\]

\\\[\\text{Weekly Emissions} = \\frac{13.3}{52} \\approx 0.256 \\, \\text{tons of CO₂ equivalent per week.}\\\]

Source : [IEA CO2 total emissions per capita by region, 2000-2023](<https://www.iea.org/data-and-statistics/charts/co2-total-emissions-per-capita-by-region-2000-2023>)

### Calculation Formula

The equivalent emissions are calculated using this formula:

\\\[\\text{Equivalent Emissions} = \\frac{\\text{Total Emissions (kgCO₂)}}{\\text{Emission Factor (kgCO₂/unit)}}\\\]

For example:

- **Car Usage**: *1 kWh* of energy consumption is approximately equivalent to:

  - *8.33 kilometers driven by a car* (*1 ÷ 0.12*).
  - *11.9 hours of TV usage* (*1 ÷ 0.084*), if emissions are considered.
- **US Citizen Emissions**:

  - *1 kWh* of energy consumption can be compared to a fraction of the average weekly emissions of a US citizen:

\\\[\\text{US Citizen Equivalent} = \\frac{\\text{Total Emissions (tons)}}{0.256}\\\]

These estimates are approximate and subject to regional variations in:

- Grid emissions intensity.
- Vehicle efficiencies.

### Source Code

The emission factors used are defined in the [CodeCarbon source code](<https://github.com/mlco2/codecarbon/blob/master/webapp/src/helpers/constants.ts>). They are based on publicly available data and general assumptions.

## Further reading

- [Accuracy and validation](<https://docs.codecarbon.io/latest/explanation/accuracy/index.md>) — measured deviations and known gaps
- [RAPL Metrics](<https://docs.codecarbon.io/latest/explanation/rapl/index.md>) — the Linux energy counters in detail
- [Power Estimation](<https://docs.codecarbon.io/latest/explanation/power-estimation/index.md>) — counters to power
- [Output reference](<https://docs.codecarbon.io/latest/reference/output/index.md>) — what each field means